How is light measured in photography?
Photographers measure light in two ways. Light falling on a scene is measured as illuminance, in lux or foot-candles. For exposure, photographers usually work in stops, also called exposure value (EV). One stop is a doubling or halving of light, and most of the exposure decisions you make with a camera are made in stops.
Lux, foot-candles and stops
- Lux is illuminance: lumens per square meter. One foot-candle is about 10.76 lux.
- Stops describe changes in light. Each stop doubles or halves the light. Full f-stops are 1.4, 2, 2.8, 4, 5.6, 8, 11, 16 and 22, and each step in that sequence changes the light by one stop.
- EV combines shutter speed and aperture for a given ISO. EV 0 is f/1.0 at one second at ISO 100. Bright sun is roughly EV 15 at ISO 100.
The sunny 16 rule
In bright sun, set the aperture to f/16 and use a shutter speed of about 1 divided by the ISO. At ISO 100, that means 1/100 second. It is a quick starting point when you have no meter, and it is the basis for shooting in bright sunlight.
Reflected, incident and spot meters
- Reflected meters measure light bouncing off the subject. Every in-camera meter is a reflected meter. They assume the scene averages out to middle gray. An 18% gray card is a common reference, though many meters are calibrated closer to 12 to 13%, depending on the maker. Very dark or very bright subjects can fool them.
- Incident meters measure the light falling on the subject. Point the white dome from the subject toward the camera. Because they ignore the subject’s reflectance, white and black subjects both expose correctly. To use one to measure a lighting ratio, see lighting ratios.
- Spot meters read a narrow angle, typically about 1 degree. Camera spot modes cover only a small percentage of the frame. Use them for high-contrast scenes.
- Flash meters capture the flash burst and give an f-stop for a set ISO and shutter speed, which is most useful when you set flash power manually. Sekonic’s L-308X and L-858D are examples.
Flash output: watt-seconds and guide numbers
Watt-seconds measure the energy stored in a flash, not the light it produces. Modifiers and reflectors change the output a lot, so don’t treat watt-seconds from different brands as directly comparable.
A guide number (GN) is the distance multiplied by the f-number at ISO 100, in meters or feet. Guide numbers aren’t directly comparable unless ISO, units and zoom setting all match. Manufacturers often quote them at a 200 mm zoom.
Is a lux meter the same as a light meter?
Not quite. A lux meter measures illuminance, which is useful for general lighting levels. A photographic light meter converts its reading into exposure settings for a given ISO. The two aren’t interchangeable without a conversion and an ISO setting.
Camera metering modes
Most cameras offer several metering modes. Names vary by brand, but the common ones are:
- Evaluative or matrix: reads the whole frame and is a sensible default.
- Center-weighted: favors the middle of the frame.
- Spot: reads a small area, often linked to the focus point.
- Partial: covers a larger central area than spot.
Check exposure with the histogram
A meter gives you a starting point. After a test shot, check the histogram and the highlight warnings on the camera. Keep important highlights from clipping, and keep important shadow detail from going to solid black. When you meter each light in a three-point setup, the histogram helps confirm the combined result.
Common misconceptions
- In-camera meters don’t measure “correct” exposure. They render snow and black cloth as middle gray, so you may need exposure compensation.
- Watt-seconds don’t equal light output. Modifiers and reflector efficiency vary hugely.
- Guide numbers can’t be compared unless the test conditions match.
- Lux meters and photographic meters aren’t interchangeable without a conversion.